WBC Count Solution (commonly manufactured or supplied as Turk’s Fluid or WBC Diluting Fluid by laboratory distributors like IBEX SCIENCES) is a quantitative diagnostic reagent used in clinical hematology. It is specifically formulated for manual white blood cell (leukocyte) counting using a hemocytometer (such as a Neubauer chamber) under an optical microscope. [1, 2, 3, 4, 5]
Core Chemical Principle & Composition
The solution relies on a dual-action mechanism to isolate white blood cells for accurate counting: [1]
- Glacial Acetic Acid (approx. 1–3% v/v): This weak acid acts as a powerful lysing agent. It completely destroys (de-hemolyzes) the non-nucleated red blood cells (erythrocytes) and dissolves their background hemoglobin. Without this lysis, the massive abundance of RBCs would physically obscure and overlap the white blood cells, making an accurate count impossible. [1, 2, 3, 4, 5]
- Gentian Violet / Methyl Violet Dye: This basic dye penetrates the remaining intact cellular membranes to stain the nuclei of the white blood cells a deep violet-blue color. This high contrast makes the leukocytes pop out vividly against a clear background. [1, 2, 3]
- Aqueous Base: Highly purified distilled water forms the matrix of the reagent, keeping the solution stable at room temperature. [1]
Standard Manual Laboratory Procedure
Manual leukocyte quantification follows a precise, sequential dilution and loading process: [1]
- Specimen Collection: Use fresh whole blood anticoagulated with EDTA. [1]
- Dilution (1:20 Ratio): Measure and draw exactly 20 µL of whole blood into a clean test tube, then add exactly 380 µL of WBC Count Solution (Turk’s Fluid). Alternatively, a standard WBC pipetting method can be used. [1, 2, 3]
- Mixing & Lysis: Tap or rock the tube gently for 3 to 5 minutes to ensure total cell suspension and complete destruction of all red blood cells. [1]
- Chamber Charging: Position a clean cover glass over a Neubauer counting chamber. Using a micropipette or capillary tube, smoothly express a drop of the mixture at the edge of the coverslip, allowing capillary action to fill the grid area completely. [1, 2, 3, 4]
- Settling: Let the chamber rest undisturbed on the bench for 2 to 3 minutes so the stained leukocytes settle evenly onto the ruled surface. [1, 2]
- Microscopic Counting: Switch the microscope to a low-power lens (typically 10x or 4x objectives). Count the number of stained cells across the four large corner squares of the Neubauer grid (each square measuring 1 mm²). [1, 2, 3, 4, 5]
Calculations
Once you have documented the cells across all four squares, the final total leukocyte concentration per microliter (μL) or cubic millimeter (mm³) of blood is determined via a standardized formula: [1, 2]
\(\text{Total\ WBC\ Count}=\frac{\text{Total\ Cells\ Counted\ }(N)\times \text{Dilution\ Factor\ }(20)\times \text{Depth\ Factor\ }(10)}{\text{Number\ of\ Squares\ Counted\ }(4)}\)
\(\text{Total\ WBC\ Count}=N\times 50\)
(Normal clinical reference ranges for healthy adults typically fall between 4,000 and 11,000 cells/mm³). [1, 2]
Crucial Bench Management & Storage
- Particulate Filtration: Over extended shelf-lives, microscopic dye crystals can slowly precipitate out of the solution. Because these floating particles can visually mimic the stained nuclei of small lymphocytes, always pass the reagent through fine filter paper if you observe debris.
- Evaporation Warning: Keep the stock container tightly capped when not in use. Acetic acid evaporation will drop the acidity profile, leading to incomplete or sluggish red blood cell lysis during diagnostics.
- Corrosive & Irritant Risks: Due to the concentrated nature of glacial acetic acid, the fluid can cause skin and eye irritation. Always perform testing while utilizing appropriate personal protective equipment (PPE), including lab coats, protective eyewear, and gloves. [1, 2, 3, 4, 5]





















Reviews